AutoMet 580
AutoMet 580 from Belfort Instrument. Powerful connectivity: Ethernet, MODBUS, 12 analog outputs, USB, RS-232C, RS-485. Statistical calculations: Avg, min, max, delta, STD DEV, dewpoint & more. Matched pyranometer inputs: For global horizontal & plane of array measurements
Features
- Powerful connectivity: Ethernet, MODBUS, 12 analog outputs, USB, RS-232C, RS-485
- Statistical calculations: Avg, min, max, delta, STD DEV, dewpoint & more
- Matched pyranometer inputs: For global horizontal & plane of array measurements
- PT-100 platinum temperature inputs:For ultra-accurate and wide range temperature measurements.
Product Specifications
| Analog Sensor Inputs | ||
|---|---|---|
| 8 single ended 0-2.5 or 0-5 VDC, with Auto ID sensor option. | ||
| 2 24BIT matched millivolt level solar radiation sensor inputs. | ||
| 3 channels PT-100 RTD temperature inputs. 24BIT, 4-wire. | ||
| Counter Inputs | ||
| 2 wind speed counters (frequency selectable as low range, high range,or low AC millivolt) | ||
| 1 rain gauge channel (de-bounced switch closure) | ||
| Digital Sensor Inputs | ||
| 1 digital sensor, up to 8 parameters. RS232 or RS485. | ||
| Supported Met One Instruments, Inc. digital sensors include but are not limited to: AIO 2, MSO-232, 597, TACMET II | ||
| Voltage Outputs | ||
| 12 voltage output channels | ||
| 16 bits unipolar | ||
| 5.000VDC full scale | ||
| (Can be scaled to 1.000 or 2.500 VDC full scale) +/- 4 millivolts accuracy (of expected reading). | ||
| Alarm Outputs | ||
| 2 alarm channels with N.O. relay contacts | ||
| (Max. power 24 VDC at 20 mA) | ||
| Communication | ||
| Ethernet serial port, 1200-115200 baud (Default 9600), ASCII, N,8,1 | ||
| USB for computer communications; shared port with Main RS-232C port | ||
| RS-232C main serial port, 1200-115200 baud (default 9600), ASCII, N,8,1 | ||
| Printer or computer RS-232C (COM2), 1200-115200 baud (default 9600), ASCII, N,8,1; | ||
| Digital sensor RS232 9600 baud fixed | ||
| RS-485 output or digital sensor input, 9600 baud | ||
| RS-232 Extra port 1200-115200 baud | ||
| Communication Protocols | ||
| MODBUS | ||
| 7500 MetRecord protocol for digital sensors | ||
| UIM serial report string | ||
| Log Channels | ||
| 16 logging channels (combination of digital and analog measurements, and calculated values). | ||
| Logging Data Capacity | ||
| 1min data 7.2 days | ||
| 5min data 36 days | ||
| 10min data 72 days | ||
| 15min data 108 days | ||
| 30min data 216 days | ||
| 60min data 433 days (1.2 years) | ||
| Power Requirement | ||
| 15VDC ± 20% | ||
| 50 mA or less (display off) | ||
| 125mA (display on) | ||
| Power Source | ||
| 120-240VAC, 50-60Hz to 12VDC power supply (included) | ||
| Solar panel array and battery (optional) | ||
| Battery and AC powered charger (optional) | ||
| Display | ||
| Backlit LCD with auto time-out | ||
| 40 character width | ||
| 8 lines | ||
| Keypad | ||
| Four operation selection keys | ||
| Four motion selection keys | ||
| Four function selection keys | ||
| Environmental | ||
| Temperature range: -20°C to +60°C (extended range available) | ||
| Humidity: 0-100%, non-condensing | ||
| Dimensions | ||
| 15.5 in (387 mm) high | ||
| 13.5 in (343 mm) wide | ||
| 6.8 in (178 mm) depth | ||
| Weight | ||
| Weight 7.8 lbs (3.5 kg) | ||
Specifications are subject to change. Contact Belfort Instrument to confirm current specifications.